Chapter 4 troubleshooting – Advantech EKI-7657C User Manual

Page 104

Advertising
background image

EKI-7657C _Manual_ed1 94

Chapter 4

Troubleshooting


Verify that you are using the right power cord/adapter (+12 ~ 48V

DC

), please don’t use

the power adaptor with DC output voltage higher than 48 V, or it will burn this converter
down.

Select the proper UTP cable to construct the user network. Use unshielded twisted-pair
(UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100 Category 3, 4 or
5 cable for 10Mbps connections, 100 Category 5 cable for 100Mbps connections, or
100

Category 5e/above cable for 1000Mbps connections. Also be sure that the

length of any twisted-pair connection does not exceed 100 meters (328 feet).


Diagnosing LED Indicators
To assist in identifying problems, the switch can be easily monitored through panel
indicators, which describe common problems the user may encounter and where the
user can find possible solutions.
If the power indicator does not light on when the power cord is plugged in, you may
have a problem with power cord. Then check for loose power connections, power
losses or surges at power outlet. If you still cannot resolve the problem, contact the
local dealer for assistance.
If the LED indicators are normal and the connected cables are correct but the packets
still cannot be transmitted. Please check the user system’s Ethernet devices’
configuration or status.