21 Chapter2

2.6 Power

Connection

The EKI-7657C supports dual +12 ~ 48 V

DC

power inputs and power-fail relay output.

Figure 2.13: Pin Assignment of the Power Connector



You can connect an alarm indicator, buzzer or other signaling equipment through the
relay output. The relay opens if power input 1, 2 fails or port link down/break (″Open″
means if you connect relay output with an LED, the light would be off).