Advantech EKI-7657C User Manual

Page 59

Advertising
background image

49 Chapter3

Port event selection: Also, before the drop-down menu items are available, the Syslog Client Mode

column on the Syslog Configuration tab/E-mail Alert column on the SMTP Configuration tab must be
enabled first. Those drop-down menu items have 3 selections—Link UP, Link Down, and Link UP &
Link Down. Disable means no event will be sent to the system log server/SMTP server.


¾

Link UP: The system will issue a log message when port connection links up only.

¾

Link Down: The system will issue a log message when port connection links down only.

¾

Link UP & Link Down: The system will issue a log message when port connection is up and

down.

Figure 3.18: Event Configuration



Fault Relay Alarm

Power Failure: Tick the checkbox to enable the function of lighting up the FAULT LED on the panel

when power fails.

Port Link Down/Broken: Tick the checkbox to enable the function of lighting up FAULT LED on the

panel when ports’ states are link-down or broken.