Topoffs

Any time the control receives a coin drop pulse during
a cycle it will add the programmed dry time to the time
currently remaining in the cycle. The maximum cycle
time is 99 minutes, the control will not add time
beyond 99 minutes. The cool down time will not
change.

If the control receives a coin drop pulse during cool
down the IN USE LED will flash briefly to indicate the
coin input, the machine will exit cool down and it will
start heating. The cycle time will be equal to the
programmed dry time

Temperature Selector Switch

For five minutes after the control is powered up, there
is a diagnostic feature that allows the temperature
selector switches to be tested.

When the temperature selector is changed, the new
setting is displayed by flashing the IN USE LED as
follows:

High/Normal: 4 flashes

Medium/PP: 3 flashes

Low/Delicate: 2 flashes

No Heat: 1 flash

NOTE: To change dipswitch settings refer to
Installation
Manual.

Error Codes

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumbler is properly grounded.

W002

WARNING

Display

Definition

Corrective Action

AF (flashing)

Airflow switch opened/closed 5 or
more times in a running cycle.

Check airflow switch. Replace if inoperative.

Advertising