Programming

1. Set DIP switch #8 to the ON position.

2. Select the desired program number to change.

The LED should be flashing.

3. Select DRY TIME. Set the time with the Up/

Down arrows.

4. Select COOL TIME. Set the time with the Up/

Down arrows.

5. Select TEMPERATURE. Set the temperature

with the Up/Down arrows.

6. Select reversing REV (illuminated) or

nonreversing REV (not illuminated). To change
basket direction and dwell time, see Reversing
Operation.

7. Press and hold the Program Select button about

3 seconds until the LED stops flashing. The
selected program number is now programmed. If
the Program button is pressed for less than
3 seconds, the controller will cancel the program
and display the next program’s settings. If not
programmed correctly, the display will flash
“E2F” for 4 seconds, and the default settings will
be used. Follow steps 4 through 7 to reprogram
any program number. When finished, set DIP
switch #8 to OFF. The programs are now stored.

8. During the Program Mode, if the Up/Down

arrows, REV, or Display button is not pressed
within 10 seconds, the default program settings will
be used.

9. Temporary Reprogramming of Current Programs

(OPL ONLY)

10. The Drying Time, Cooling Time, Temperature,

and Reversing Mode of a program currently in
use may be modified simply by adjusting any or
all of the program parameters for that program,
as needed. Once a modification has been made,
the current program LED will flash indicating
that it has been modified.

11. Use the Up/Down arrows to adjust program time.

12. Use the Display Select button to choose between

Drying Time, Cooling Time, and Temperature.
Then use the Up/Down arrows to adjust the times
and temperature.

13. Toggle between reversing REV (illuminated) or

nonreversing REV (not illuminated). (Only for
tumblers with the reversing option.)

14. To cancel this temporary programming mode

push the STOP button once to stop the current
cycle and once more to cancel the modified
program settings. The program will revert back
to its original settings.

Reversing Operation

1. When the LOCAL reversing operation is

selected, the reversing times are stored in the
EEPROM which is located on the controller
board. If the values stored are determined to be
invalid, the clockwise and counterclockwise
times will default to 60 seconds, and the dwell
time will default to 4 seconds.

2. The reversing time program has the following

sequence: (1) clockwise time, (2) dwell time, and
(3) counterclockwise time.

3. To program new reversing times DIP switches #3

and #8 must be on.

4. Press and hold the reverse button (REV) for

3 seconds to display the clockwise time.

5. Use the Up/Down arrows to set the clockwise

time within the range of 30-120 seconds.

6. Press REV to display the dwell time.

7. Use the Up/Down arrows to change the dwell

time within the range of 3-10 seconds.

8. Press the REV button to display the

counterclockwise time.

9. Use the Up/Down arrows to change the

counterclockwise time within the range of
30-120 seconds.

10. Press the REV button to save these settings and

leave DIP switch #3 in the ON position and flip
DIP switch #8 to the OFF position.

When the DMP controller is retrofitted to an existing
tumbler with the reversing feature, off board reversing
will be required and DIP switch #3 on the DMP must
be in the OFF position and the DMP must be
connected to the Reversing Timer Board for proper
operation. The DMP settings for clockwise, dwell, and
counterclockwise times are no longer valid when used
with the Reversing Board. Instead these settings are
made on the Reversing Timer Board.