Outer diameter control sensor, Printer, Applicator – Avery ALS 256 User Manual

Page 24: Applicator interface, Dust/splash guard

Advertising
background image

20

C

ONTENTS

2.2 O

PTIONS

ALS

20x
256

GB

Outer Diameter control sensor

The outer diameter control sensor (OD sensor) triggers
a warning, if the label roll outer diameter falls below a
certain, adjustable value.

Printer

– If necessary, you can mount a hot stamp printer (not

available from Avery Dennison) onto the holder
brackets of the dispensing edge.

– Example of use: Printing consecutive numbers onto

labels.

Applicator

If it is not possible to label directly from the dispensing
edge, you can fit an applicator to the label dispenser.
Various types of applicators are available that depend
on the given requirements.

Simple applicators can be controlled directly via the
PLC signal interface [5G] that is available as standard.

Applicator interface

Additional board [5H]; allows almost all types of
applicators to be controlled.

Dust/Splash guard

Available only for ALS 20X.

Additional sealing of the electrical connections and of
the housing fulfils the requirements of the IP65
protection class [19].

[18] OD sensor (pictured red resp. dark gray)

[19] Dust/splash guard of the electrical connections (pictured red

resp. dark gray)