CAUTION:

Never use straight gasoline in

your unit. This will cause permanent engine

damage and void the limited warranty. Do not

use alternate fuels such as ethanol blends

above 10% by volume (E-15, E-85) or any

methanol blended fuel. Use of these fuels can

cause major engine performance and durability

problems.

BAR AND CHAIN LUBRICATION

The bar and chain require lubrication. The chain

oiler provides continuous lubrication to the chain

and guide bar. Be sure to fill the bar oil tank

when you fill the fuel tank (Capacity = 4.6 fl. oz.).

Lack of oil will quickly ruin the bar and chain.

Too little oil will cause overheating shown by

smoke coming from the chain and/or discolor-

ation of the bar. The oil output is automatically

metered during operation. Always fill the bar oil

tank when you fill the fuel tank.

Genuine Poulan or Poulan PRO bar and

chain oil is recommended to protect your unit

against excessive wear from heat and fric-

tion. Poulan or Poulan PRO oil resists high

temperature thinning. If Poulan or Poulan

PRO bar and chain oil is not available, use a

good grade SAE 30 oil.
S

Never use waste oil for bar and chain

lubrication.

S

Always stop the engine before removing

the oil cap.

HOW TO STOP YOUR UNIT

S

Release the throttle trigger.

S

Push and release the engine ON/STOP

switch. The switch will automatically return

to the ON position. Wait 5 seconds before

attempting to restart unit to allow switch to

reset.

ON/STOP

Switch

HOW TO START YOUR UNIT

WARNING:

Make sure the chain will

not make contact with any object while start-

ing the engine. Never try to start the unit when

the guide bar is in a cut. Avoid any contact

with the muffler. A hot muffler can cause seri-

ous burns.

Starting position

HELPFUL TIP

If your engine still does not

start after following these

instructions, please call

1--800--554--6723.

STARTING A COLD ENGINE

NOTE:

DO NOT squeeze the throttle trigger

until the engine has started and runs.

1. Set unit on a flat surface.

2. Slowly press the primer bulb 6 times.

3. Move the start lever to the START posi-

tion.

Primer Bulb

Start Lever

Starter Handle

4. Pull starter rope handle sharply until en-

gine starts and runs.

5. Allow unit to run for 10--15 seconds, then

fully squeeze the throttle trigger to disen-

gage the starting system.

STARTING A WARM ENGINE

1. Squeeze and hold the throttle trigger.

2. Pull starter rope sharply while squeezing

throttle trigger until engine runs.

NOTE:

Normally, the warm starting proce-

dure can be used within 5--10 minutes after

the unit is turned off. If the unit sits for more

than 10 minutes without being ran, it will be

necessary to start the unit by following the

steps under STARTING A COLD ENGINE or

following the starting instruction steps shown

on the unit.

STARTING A FLOODED ENGINE

Flooded engines can be started by placing

the start lever to the RUN position. Fully

squeeze throttle trigger. Pull the starter han-

dle repeatedly while squeezing throttle trigger

until engine starts and runs. This could re-

quire pulling the starter handle many times,

depending on how badly the unit is flooded.

If the unit still doesn’t start, refer to

TROUBLESHOOTING

TABLE

or

call

1-800-554-6723.

Advertising