Operation – Poweramp TPR SERIES User Manual

Page 25

Advertising
background image

23

4111-0035 — Feb 2012
Aug 2012

OPERATION

RELEASE Button Pressed - Restraint DISENGAGING
Hook travels from the ENGAGED position to the STORED
position. Outside light is flashing RED alerting truck driver
not to move. Inside light is flashing RED. Once the hook
is stored the outside light with flash GREEN, alerting the
drive it is safe to depart.

FAULT from ENGAGING State
Hook cannot engage the RIG. This could be due to a RIG
that is located too far toward the rear axle, bent, obstructed
or missing. Inside light is flashing red and yellow light is
flashing, alerting the forklift operator that the trailer is
not locked. Outside light is flashing red alerting the truck
driver not to move.

If the trailer is parked firmly against the dock bumpers
proceed to BY PASS. If not, press RELEASE to clear the
fault, have trailer back up and repeat Restraint ENGAGING.

RED

RED

BY PASS

YELLOW