Cfip phoenix m odu – SAF Tehnika CFIP PhoeniX and PhoeniX M ETSI V1.3 User Manual
Page 8
© SAF Tehnika JSC
Ver. 1.3, 2012 March
CFIP PhoeniX series
Hybrid split mount system
CFIP PhoeniX M ODU
* Under development. Actual data may differ by a small margin
CFIP ODU with CFIP PhoeniX M IDU RSL at 10
-6
(dBm) and Total Payload Capacity (Mbps)*
Modulation
Channel bandwidth (MHz)
7 14 28 40 56
RSL
dBm
Bit rate
Mbps
RSL
dBm
Bit rate
Mbps
RSL
dBm
Bit rate
Mbps
RSL
dBm
Bit rate
Mbps
RSL
dBm
Bit rate
Mbps
QPSK
-91
8
-89
17
-87
36
-85
52
-83
74
16APSK
-86 16 -83 36 -80 74 -78 108 -76
144-152
32APSK
-83
21
-80
46
-76
94
-75
132
-73
192
64QAM
- - -76 55 -73 112 -72 164 -70 232
128QAM
-
-
-
-
-71
128-136
-69
188
-67
264
256QAM
- - -
-67
144-160
-66
224
-62
312-348
CFIP ODU Tx Power
Modulation
Standard/High Tx Power, dBm
6, 7, 8 GHz
10, 11, 13, 15 GHz
18, 23, 26* GHz
38* GHz
QPSK
+19 / +27
+19 / +25
+19
+17
16APSK
+18 / +26
+18 / +24
+18
+16
32APSK
+17 / +25
+17 / +23
+17
+15
64QAM
+15 / +23
+15 / +21
+15
+13
128QAM
+15 / +23
+15 / +21
+15
+13
256QAM
+12 / +20
+12 / +18
+12
+10
CFIP ODU waveguide flange sizes
6 GHz 7, 8 GHz 10, 11 GHz 13, 15 GHz 18, 23 GHz
24 GHz
26 GHz 38 GHz
N-type
UBR84
UBR100
UBR140
UBR220
Circular 10mm UBR260 UBR320
Max. Power
consumption
SP: 13-27 W; HP: 21-39 W