11.

Fit a spring washer, flat washer and a nut
on every stud and tighten them up. Spin the
rotor with an air drill and the shaft
attachment. Fit M10 x 35 studs to top of
Stator

12.

Fit remaining dowels, the inlet connection
and gasket. The side tapping on the inlet
connection must face towards the oil
connection on the drive end plate. Secure
with nuts and washers.

13.

Fit the static part of the magnetic clutch
assembly to the drive-end bearing housing
using the UNC screws provided.

14.

Remove the grub screw from the drive end
bearing housing and insert the anti-rotation

tool.

15.

Fit the key (19), coat the shaft taper with
anti-seize grease and fit the pulley using
the washer and screw supplied with the
clutch.

16.

Remove the anti-rotation tool and replace
the grub screw having sealed the threat
with PTFE tape.

Note: Where required, the magnetic clutch may

be replaced by a direct drive pulley (29) that
is fitted as per paragraphs 14, 15 & 16
above but with Loctite 270 applied to the
retaining screw (31) before final assembly.


7.6 Priming Tank Assembly

7.6.1 Priming Tank Parts Diagram

13

12 7 8

6 18

14

21

15

17

19

25

25a

11

16

4

5

10

2

1

24

24a

24b

3

22

23 & 23a

30

29

26

27

28

31

Note: Items 32 to 35 are not shown