- Disassemble the suction and outlet valve units, screwing a sufficiently long M10 screw in such a way

as to be able to reach the valve plate and extract the valve guide from the valve seat (fig. 17, 1).

2.2.2 REASSEMBLING THE HEAD - VALVE UNITS

Pay particular attention to the conditions of the various components and replace if necessary, and at

intervals indicated in the ‘PREVENTIVE MAINTENANCE” on the specification sheet.

At every valve inspection, replace all O-rings and all anti-extrusion rings both in the valve

groups and on the valve plugs.

Before repositioning the valve unit, thoroughly clean and dry the relative seats in the head as shown

in fig. 18.