Htck4050s – General Pump HTCK4050S User Manual

Page 5

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

HTCK4050S

Page 5

-Remove the pump shaft

-Complete disassembly of the con-rod units by removing them from the pump casing and removing

the plunger guide pins

-Remove the pump shaft seal rings using common tools

-Remove the plunger guide seal rings as described below:

Use the extractor, p/n 26019400 (fig. 5, 1) and the gripper p/n 27503900 (fig. 5, 2). Insert the gripper as far as

possible onto the seal ring with the aid of a hammer (fig. 5a), subsequently screwing the extractor to the grip-

per, and use the extractor hammer (fig. 5b) until the ring to be replaced is removed (fig. 5c).

-push the plunger guides forward with their con-rods to facilitate side extraction of the pump. Two

references are visible on the shaft (indicated with the number 1 in figs. 4 and 4a). These should be

turned toward the operator to facilitate extraction.

Ref 300934 Rev.A

09-13

Advertising