Htck4050s – General Pump HTCK4050S User Manual

Page 17

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

HTCK4050S

Page 17

Ref 300934 Rev.A

09-13

4. REPLACING THE CONNECTING ROD FOOT BUSHING

During maintenance, if it becomes necessary to replace the connecting rod foot bushing, proceed as follows:

When removing the worn bushing, take great care not to damage or scratch the seat on the

connecting rod.

Perform cold press fitting of the new bushing. During this operation, ensure that:

• the lubrication hole coincides with the corresponding hole on the connecting rod;

• the cutting junction is directed as shown in fig. 26

Then perform mechanical processing. The dimensions and tolerances shown in fig. 26 MUST be

respected.

Advertising