Kez series, General pump – General Pump KEZ Repair Manual User Manual

Page 10

Advertising
background image

2.2.2 Head assembly - valve units

Pay careful attention to state of wear of the various components; replace them when necessary, and

in any case within the intervals indicated in the table in fig. 14, Chapter 11 of the Owner’s Manual.

At each inspection, replace all valve units and valve plugs OR rings and enti-extrusion rings.

Before repositioning the valve units, clean and perfectly dry the relevant seats in the head as

indicated in fig. 14.

GENERAL PUMP

A member of the Interpump Group

KEZ SERIES

Page 10

Disassemble the valve assemblies with simple tools - a couple of screw drivers (fig. 13) would work more than fine.

Components valve assemblies are pressed together with a minimal load, therefore the job results extremely

easy to be carried out. Being the valve cages are made of polymer, attention should be taken during service in

order to prevent the cage ribs from being damaged.

fig. 13

fig. 14

Proceed with reassembly by inverting the proceedure indicated in paragraph 2.2.1.

During the assembly of the suction and delivery valve units (fig. 15 - fig. 16) do not invert the suction

springs with the previously disassembled delivery springs:

a)

Suction springs “white”

b)

Delivery springs “black”