Kez series, General pump – General Pump KEZ Repair Manual User Manual

Page 13

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

KEZ SERIES

Page 13

2.2.4 Plunger Unit Disassembly

The plunger unit does not require periodical maintenance. Service interventions are limited to visual

inspections only. For plunger unit extraction, operate as follows:

A) Unfasten the plunger screws as shown in fig. 20.

fig. 19

B) Check for wear; replace if necessary.

At each disassembly, all plunger unit O-rings MUST be replaced.

2.2.5 Head assembly - seals - plunger unit

Reassemble the various components by inverting the operations previously listed in paragraph 2.2.3, paying careful

attention to the following:

A) Seal packing: respect the same order followed during disassembly.

B) Lubricate components 3 and 5 with silicone grease type (#F12001600) on outer diameter only.

C) Fore ceorrectly assembling the HP seals in their related seats on the head, use the correct tools as indicated in

Section 4.

D) Reassemble the plungers by fastening the screws with a torque wrench, respecting the fastening torque

value inicated in Section 3.

E) Assemble the head: for fastening torque values and fastening sequences, follow the instructions in Section 3.

Advertising