Kez series, General pump – General Pump KEZ Repair Manual User Manual

Page 8

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

KEZ SERIES

Page 8

Determine the shim pack as indicated in the table below.

fig. 10

Measurement

Shim Type # Pieces

From: 0.05 to: 0.10

/

/

From: 0.11 to: 0.20

0.1

1

From: 0.21 to: 0.30

0.1

2

From: 0.31 to: 0.35

0.25

1

From: 0.36 to: 0.45

0.35

1

From: 0.46 to: 0.55

0.35

0.10

1

1

From: 0.56 to: 0.60

0.25

2

From: 0.61 to: 0.70

0.35

0.25

1

1

E) Insert the shims under the cover on the sight glass side (see fig. 11), fixing it to the crankcase using the

appropriate screws, and verifying that the stall torque is between 3-4 ft. lbs. (4-6 Nm).

F) If the torque values is correct, connect the rods to the crankshaft; other wise, redefing the shims again

repeating the operations from point “C”.

Advertising