Kez series, General pump – General Pump KEZ Repair Manual User Manual
Page 8
Advertising
![background image](/manuals/347262/8/background.png)
GENERAL PUMP
A member of the Interpump Group
KEZ SERIES
Page 8
Determine the shim pack as indicated in the table below.
fig. 10
Measurement
Shim Type # Pieces
From: 0.05 to: 0.10
/
/
From: 0.11 to: 0.20
0.1
1
From: 0.21 to: 0.30
0.1
2
From: 0.31 to: 0.35
0.25
1
From: 0.36 to: 0.45
0.35
1
From: 0.46 to: 0.55
0.35
0.10
1
1
From: 0.56 to: 0.60
0.25
2
From: 0.61 to: 0.70
0.35
0.25
1
1
E) Insert the shims under the cover on the sight glass side (see fig. 11), fixing it to the crankcase using the
appropriate screws, and verifying that the stall torque is between 3-4 ft. lbs. (4-6 Nm).
F) If the torque values is correct, connect the rods to the crankshaft; other wise, redefing the shims again
repeating the operations from point “C”.