Conclusion: using a dynamometer, by loading the belt with 75 N as indicated in fig. 13, you will obtain a flexion value “te”

of about 10.8 mm.

Note 1. If not differently indicated by the belt Manufacturer, the inspection of the correct tension value, and the related

tension adjustment if needed, is to be carried out after at least 30 minutes of operation in order to obtain belt settling.

The best efficiency and maximum duration is obtained with the correct tension value.

Note 2. If required, or during normal maintenance, never replace a single belt, rather the entire set.