Ks series, General pump – General Pump KS Owner Manual User Manual

Page 9

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

KS SERIES

9.3 Version Change

A right version pump is defined when: Observing the pump

from the head side, the PTO shank of the pump shaft is on

the right side.

A left version pump is defined when observing the pump

from the head side, the PTO shank of the pump shaft is on

NOTE: Figures 5 and 5a show right versions.

The version may be changed only by specialized and

authorized personnel by carefully following the

instructions that follow:

1. Separate the hydraulic part from the mechanical part.

2. Rotate the mechanical part by 180

0

, and reposition the

rear crankcase cover so that the oil dipstick is facing

upwards; reposition the lifting bracket and the related

closing caps in the upper part of the crankcase; finally,

correctly reposition the identification plate in its

appropriate seat on the crankcase.

Be sure that the lower draining holes on the

crankcase near the plungers are open, and not

closed by the plastic caps as required for the

previous version.

3. Join the hydraulic part with the mechanical part.

It is furthermore possible to set the reducer in 4 different

positions as shown in fig. 6.

9.4 Hydraulic Connections

In order to isolate the system from the vibrations produced

by the pump, we advise to build the first section of the duct

near the pump (both for intake and delivery) with flexible

tubes. The consistency of the intake section must allow to

avoid deformation caused by the depressurization pro-

duced by the pump.

9.5 Pump Feeding

KS pumps require a minimum positive head (NPSH

r

),

measured on the head intake flange, indicated in the

following table (obtainable by the means of a booster

pump):

The reducer’s position may be changed only

by specialized and authorized personnel by

carefully following the above directions.

KS28A

KS32A

KS36A

KS40A

NPSH

r

(m)

2.0

2.5

3.0

4.0

The booster pump must have the following characteristics:

• Flow rate of at least twice the value of the plunger

pump’s rated flow value, with a minimum pressure

sufficient for the required NPSH

r

and max 87 PSI.

These feeding conditions must be respected in all running

conditions. Booster activation must be independent from

that of the plunger pump.

Booster start-up must always precede plunger

pump start-up. In order to protect the pump,

we advise to install a pressure switch on the

feeding line after the filters.

For feeding conditions that differ from that speci-

fied above, please contact the Technical or

Customer Service Department.

9.4 Suction line

For the pumps correct operation, the suction line must have

the following characteristics:

1. Minimum internal diameter as indicated in the diagram

in paragraph 9.9, and in any case equal or greater than

the pump head’s value.

Along the duct, avoid localized diameter reduction

that may cause pressure drops with subsequent

cavitation. Absolutely avoid 900 elbows, with other

tubes, pipes, bottlenecks, counter-slopes, upside-

down “U” shaped curved and “T” connections.

2. The selection position must avoid cavitation.

3. It should be perfectly airtight, and built in a way that

guarantees

perfect

sealing

over

time.

4. Avoid pump emptying when stopping (even partial

emptying).

5. Do not use hydraulic-type fittings, 3- or 4-way fittings,

adapters, etc., since they may hinder the pump’s

performance.

Page 9

Ref 300655 Rev D

09-12

Advertising