Ks series, General pump – General Pump KS Owner Manual User Manual

Page 3

Advertising
background image

Page 3

GENERAL PUMP

A member of the Interpump Group

KS SERIES

1. INTRODUCTION

This manual describes the use and maintenance instruc-

tions of the KS pump, and should be carefully read and

understood before pump operation. Correct use and ade-

quate maintenance will guarantee the pumps trouble-free

operation for a long time.

General Pump declines any responsibility for damage

caused by misuse or the non-observance of the

instructions indicated in this manual.

Upon receiving the pump, check that it is complete and in

perfect condition. Should anything be found out of order,

please contact us before installing and starting the pump.

3. SAFETY

3.1 General safety indications

The misuse of pumps and high pressure units, and the

non-observance of installation and maintenance

instructions may cause severe injury to people and/or

damage to property.

Anyone requested to assemble or use high pressure units

must possess the necessary competence to do so, should

be aware of the characteristics of the components

assembled/used, and must adopt all the necessary

precautions in order to guarantee maximum safety in any

operating condition. In the interest of safety, no

precaution that is reasonably feasible must be neglected,

both by the Installer and the Operator.

3.2 High pressure unit safety requirements

1. A safety valve should be installed in any delivery line

and should be sized to discharge or by-pass the

entire pump flow rate

2. High pressure unit components, with particular regard

for those units working outside, should be adequately

protected against rain, frost and heat.

3. Electric components and wiring should be provided

with an adequate degree of protection, able to protect

them against spray coming from any direction. They

should also be suitable for working in a wet

environment.

4. High pressure hoses and any other accessory under

pressure should be sized in accordance with the

maximum unit working pressure and must always

work within the safety margins indicated by the hose/

accessory Manufacturer.

5. High pressure hose ends should be fastened to a

steady object in order to prevent them from

dangerous sweeping around, should they burst or

come off their end fittings.

6. Proper safety guards should be provided to

adequately cover transmission joints, pulleys, belts or

auxiliary drives.

2. SYMBOL DESCRIPTIONS

Warning

Potential Danger

Danger

Electrocution Danger

Danger

Use a face guard

Danger

Use protective glasses

Danger Signal

Use adequate hand protection

before operating the pump

Danger

Wear protective boots

Carefully read the indications in

this manual before operating the

pump.

Ref 300655 Rev D

09-12