The pump’s shaft (PTO) must not be rigidly connected to the motor unit.

The following transmission types are suggested:

• Flexible joint

• Cardan Joint (please respect the maximum working angles indicated by the manufacturer)

9. PUMP INSTALLATION

9.1 Installation

The pump must be installed in a horizontal position using the drilled Ø19 support feet. The base must be perfectly flat and

rigid enough as not to allow bending or misalignment on the pump coupling and axis/transmission due to torque transmit-

ted during operation.

Two lifting eyebolts are mounted on the pump for easy installation, as per the figure below.

9.2 Direction of rotation

The PTO rotation is indicated by an arrow located on the reduction gear cover. From a position facing the pump head,

the rotation direction will be as in fig. 6.