7.4 Recommended Lubricant Oil Types & Manufacturers
The pump is delivered with lubricant oil compliant with room temperatures ranging between 32

o

and 89.6

o

F (0

o

and

30

o

C ). Some recommended lubricant types are indicated in the table below; these lubricants are treated with additives

in order to increase corrosion protection and resistance to fatigue. As an alternative, Automotive SAE 85W-90 gearing

lubricants may also be used.

BRAND

TYPE

GENERAL PUMP

SERIES 220

ARAL

Aral Degol BG220

BP

ENERGOL HLP 220

CASTROL

Hyspin VG 220, Magna 220

ELF

POLYTELIS 220

ESSO

NUTO 220

FINA

Cirkan 220

FUCHS

RENOLIN 220

MOBIL

DTE OIL BB

SHELL

TELLUS C 220

TEXACO

RANDO HD 220

TOTAL

CORTIS 220

Check the oil level with the oil level lights located on the sides (1, fig. 3). If necessary, top off via the

oil plug (3, fig. 3).

To correctly check the oil level the pump must be at ambient temperature. To change the oil the pump

must be at operating temperature, and is done by removing the plug (2, fig. 3).

Checking and changing the oil must be done as shown in Chapter 11. The quantity necessary is 473.4

oz. (14 liters).