6. DIMENSIONS AND WEIGHT

fig. 2

Weight: 840 Lbs./381 Kg.

For dimensions and weight, please refer to fig. 2.

7. INFORMATION ABOUT PUMP USE

The SK pump was designed to operate with filtered water (see paragraph 9.7) and at
maximum temperature of 104

o

F (40

o

C).

Other fluids may be used only upon the approval of The Customer Service Department .

7.1 WaterTemperature
The max water temperature is 104

o

F (40

o

C).However, it is possible to use the pump at temperatures of up

to 140

o

F (60

o

C) for short periods of time. In this case we advise consulting the Customer Service

Department.

7.2 Max Flow Rate and Pressure Values

The performance values indicated in the catalog refer to the maximum performance of the pump. Regardless of the power

used, pressure and maximum RPM values indicated on the plate may not be exceeded unless expressly authorized by the

Customer Service Department.

7.3 Lowest RPM

Any RPM value different from what is indicated in the performance table (see chapter 5) must be explicitly authorized by

the Customer Service Department.