Vh series, General pump – General Pump VH User Manual

Page 10

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

VH SERIES

11.2 Fluid end maintenance

The fluid end does not require periodical maintenance.

Service operations are limited to valve inspection

and/or replacement, when necessary.

Remove the pump head (1, Fig. 12).

When removing the head from the pump pay attention

to the valve seats (1, Fig 13) and the suction valve

poppets (2, Fig. 13) which may fall off the head. Check

the cooling system orifices of the head (see arrows) and

the relevant white tips (3, Fig. 3) for deposits or sediments

that may prevent cooling water from flowing through.

Loosen and remove the 8 head screws (1, Fig. 11).

Once removed take out the delivery valve guide with the

spring and valve poppet. AN M8 threaded bolt to be used

as a simple extractor would help the operation (see

Fig. 10).

In order to have access to the delivery valves loosen the

12 valve cover screws (1, Fig. 9) and remove the covers.

Remove the valve seats (1, Fig 14) from the head, check

them for wear and replace if necessary.

BEFORE REPOSITIONING THE VALVE UNITS BACK

IN PLACE CLEAN AND PERFECTLY DRY ALL VALVE

HOUSINGS INSIDE THE HEAD.

VALVE RINGS (2, FIG. 14) AND ALL O-RINGS SHOULD

BE REPLACED AT EVERY INSPECTION.

Page 10

Advertising