Vh series, General pump – General Pump VH User Manual

Page 13

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

VH SERIES

Each pressure packing set component should fit tight in

the cylinders. A pin of adequate dimension (1, Fig. 27)

helps in guiding each component straight and aligned all

the way down the cylinder.

Page 13

Fit each new component of the pressure packing set in

the cylinder making sure of the correct order as shown

in Fig 26:

1. Packing bushing

2. Packing ring

3. Back packing

4. Pressure Packings

5. Pressure packing retaining bushing

Fit the packing support nut back in place and tighten. The

new rear seal should be mounted with the larger

diameter side in first, as shown in Fig. 28.

Reassemble the pump by following the

disassembling steps in the opposite sequence

and use a torque wrench for the screws listed

below:

-Plunger screws: 28.9 ft. lbs.

-Head screws: 133.8 ft. lbs.

-Valve cover screws: 54.2 lbs.