7. GENERAL INFORMATION ABOUT PUMP

USE

The VH pump has been designed to pump fresh filtered

water at room temperature.

7.2 Max flow and pressure ratings

The performance data indicated in the catalog and on the

rating plate refer to the maximum performance of the

pump. The use of the pump below the rated performances

does not allow the drop in power absorbed to be balanced

by altering the pressure or volume of the pump above its

maximum value.

7.3 Lowest operating RPM

The lowest operating speed for all VH pumps (all versions)

is 500 RPM.

8. CONNECTIONS AND PLUGS

VH pumps are provided with (Fig. 3):

1 - 2 inlet ports IN G 3/4”

Suction line connection to either inlet port is

acceptable, the port not being used should be

sealed with the correct plug.

2 - 2 outlet ports OUT Ø 8 mm”

3 - 2 outlet ports OUT Ø G 1/2” (designed for pressure

gauge and safety valve only)

4 - 1 hole DRAIN provided with quick coupling for

connection with Rilsan air hose Ø mm; it collects

the water drainage from the cooling system and

should be connected back to the suction line BEFORE

the feed pump.

7.1 Water temperature

The max water temperature is 30oC (86oF)

The VH pump is supplied with 4 conical seals (Fig 4)

made of stainless steel and designed to provide total

sealing of the outlet connections. They must be used in

either the outlet ports of the head or in the outlet ports

of the optional outlet mounting flanges. The conical

seals should be replaced at any disassembling and

not re-used.