Step-by-step wiring diagrams

WIRES

2 Wire Heat GAS MILLIVOLT or 24VAC system

STEP 1 - Connect the R (or RH) wire to the RH terminal. This connects the heat power.

STEP 2 - Connect the W wire to the W terminal. This connects the heat.

STEP 3 - Set HVAC selection switches to NORMAL and GAS.

Your heater is now connected to the LS-60.

Please Go To Page 6

WIRES

3 Wire Heat

STEP 1 - Connect the R (or RH) wire to the RH terminal. This connects the heat power .

STEP 2 - Connect the W wire to the W terminal. This connects the heat.

STEP 3 - Connect the G wire to the G terminal on the thermostat. This connects the fan.

STEP 4 - Set HVAC selection switches to NORMAL and:

If you have gas or oil heat, set the HEAT TYPE to GAS.

If you have electric heat, set the HEAT TYPE to ELEC.

Your system is now connected to the LS-60.

Please Go To Page 6

W

R

C

C H B O W

2

W

Y Y

2

RH RC G A

RADIO POWER

W R

G

C

HVAC SYSTEM

REMOTE POWER

C H B O W

2

W

Y Y

2

RH RC G A

AC SYSTEM