Find the step-by-step diagram for your system, C w y rh rc g, C w y rh g – LOCKSTATE LS-60 Installation Guide User Manual

Page 5: C w rh g, C w rh, W rh a, C w2 w y y2 r, O y r

Advertising
background image

PG

4

PG

4

PG

5

Find the step-by-step diagram for your system

• Select the referenece

page with your wiring

diagram and set-up

information below.

• The C-wire is optional but

prefered for all installations

[shown dotted in diagrams].

Some radio modules will

require the 24VAC C-wire

power.

• If your combination of

wires is not above you can

use the wiring table at the

end if the install section to

determine your connections,

contact customer support

for help.

G

C W Y RH RC G

5 Wire

Heat/Cool

F

rom

F

urnace

RC

C

Y RH

W

C W Y RH G

4 Wire

Heat/Cool

F

rom

F

urnace

G

C

Y RH

W

C W RH G

3 Wire

Heat

F

rom

F

urnace

C

R

H

G

W

F

rom

F

urnace

C

W

C W RH

R

H

2 Wire

Heat

F

rom

F

urnace

W

R

H

A

W RH A

3 Wire

Zoned

Hot Water

W

IRES

WIRES

WIRES

WIRES

WIRES

G

RH

C W2 W Y Y2 R

H

G

2 stage Cool

2 stage Heat

F

rom

F

urnace

Y

2

C

W

Y

W

2

C B

or

O W

2

Y R

H

G

5 Wire

Heat Pump

w/ Aux Heat

F

rom

F

urnace

R

H

C

O

or

W

2

B

G

Y

G

C B

or

O Y R

H

G

4 Wire Heat Pump

w/o Aux Heat

F

rom

F

urnace

R

H

C

O

or

Y

B

WIRES

WIRES

WIRES

Go To Page 13

Go To Page 13

Go To Page 14

Go To Page 14

Go

To

Page 16

Go To Page 15

Go To Page 15

Go To Page 16

from

HVAC

from

HVAC

from

HVAC

from

HVAC

from

HVAC

from

HVAC

from

HVAC

from

HVAC

Advertising