Command Type (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

For Gun and Channel Codes, the gun or channel number appears in the lower nibble.

System Codes / Error Description: 0xB000

=

System

Halted

0xB010

=

Remote

I/O

(RIO)

Communication

Error

0xB020

=

Invalid

RIO

BTW

Code

0xB030

=

Invalid

RIO

BTR

code

0xB040

=

Invalid

RIO

BTW/BTR

Gun/Channel

Number

0xB050

=

Invalid

RIO

BTW/BTR

Job

Number

0xB060

=

Invalid

RIO

BTW

W

ord

Count

Gun Codes / Error Description: 0x202g

=

Pot

Life

T

ime

Exceeded

0x205g

=

Out

of

Ration

0x206g

=

Gun

Not

Ready

0x207g

=

Gun

Busy

0x908g

=

No

External

Gun

Enable

0xA02g

=

Flow

Rate

Out

of

Range

(Low

or

High)

Channel Codes / Error Description: 0x901c

=

Ratio

Out

of

T

olerance

0x902c

=

Reverse

Flow

V

olume

Exceeded

0x903c

=

Flow

Rate

T

oo

Low

0x904c

=

Flow

Rate

T

oo

Low

0x905c

=

Duplicate

Channel

Assigned

0x906c

-

Ki

Parameter

T

oo

Small

0x907c

=

No

Master

Flow

Rate

0x909c

=

Channel

Not

Present

0x91

1c

=

Out

of

T

olerance,

Slave

Flow

Rate

T

oo

High

0x921c

=

Out

of

T

olerance,

Slave

Flow

Rate

T

oo

Low

Note: If sent unsolicited, only <E1><E1> should be evaluated by the User Interface, as the message was sent to report a System fault. Gun faults are received in the Gun Status word in a

Type <06> message.

<08>

Request for Start Calibration for a Channel: <08><LL><0C><CN><CN><CS><CS> Where: 1) <LL> = message length = <05h>. 2) <0C> = Channel #. 3) <CN><CN> = Calibration control word (see below). 4) <CS><CS> =

Automatic Mode Calibration set point,

else <00><00>.

Response:

ACK <FF>