Command T

ype (hex)

Response Or

Action From User Interface

Response Or

Action From Interface Module

Calibration Control word: Bit 0 = Manual Mode (1),

Auto Mode (0).

Bit 1 = Save New P/L

to Current Job.

Bit 2 = Save New P/L

to

All Jobs.

Bit 3 = Populate Lookup

Table.

<09>

Request for Engineering Backdoor data:

<09><LL><0G><JJ>

Where: 1) <LL> = message length = <02h>. 2) <0G> = Gun #. 3) <JJ> = Job #.

Response:

<09><LL><0G><JJ><AN><PT><A

T><KP><KP><KI><KI><KD>

<KD><CP><CP><CI><CI><CD><C

-

D><OP><OP><OI><OI><OD> <OD><UG><UG><UP><UP><DC><DC><DP><DP><CS><CS> <TS><TS><L

T><L

T><FR><FR><MC><MC>

Where: 1) <LL> = message length = <29h>. 2) <0G> = Gun #. 3) <JJ> = Job #. 4) <AN> =

Algorithm #.

5) <PT> = PID Update

Time.

6) <A

T> =

Auto-tune Procedure

<00> = Open Loop <01> = Closed Loop 7) <KP><KP> = Proportional contribution to voltage output. 8) <KI><KI> = Integral contribution to voltage output. 9) <KD><KD> = Derivative contribution to voltage output. 10) <CP><CP> = Calculated proportional closed loop gain. 1

1) <CI><CI> = Calculated integral closed loop gain.

12) <CD><CD> = Calculated derivative closed loop gain. 13) <OP><OP> = Calculated proportional open loop gain. 14) <OI><OI> = Calculated integral open loop gain 15) <OD><OD> = Calculated derivative open loop gain. 16) <UG><UG> = Ultimate gain for closed loop tuning. 17) <UP><UP> = Ultimate period for closed loop tuning. 18) <DC><DC> = Calculated % of full scale change of output voltage in open loop mode. 19)

<DP><DP>

=

Calculated

%

of

full

scale

change

of

fluid

flow

in

open

loop

mode.

20) <CS><CS> = Calculated slope in open loop mode. 21) <TS><TS> = Measured lag time in open loop mode. 23) <FR><FR> = Filter in open loop mode. 24) <MC><MC> = Misc. Control word in open loop mode.

35