Vector R Series Classic Applicators - Maintenance

43

Ransburg

AH-06-02.12

Figure 27: Hook Insertion Into Handle

4. Push the hook gasket into the groove of the

hook. Apply a light coat of dielectric grease

(LSCH0009) to the hook gasket exterior and slide

the hook into position.

5. Reinstall the air valve components in the reverse

order of disassembly.

6. Push the rear cover onto the back of the handle.

Secure the cover by inserting the fan air adjustment

valve into the handle and tighten in the clockwise

direction.

7. Insert the barrel gasket back into the handle.

NOTES