TROUBLESHOOTING GUIDE

(Cont.)

General Problem

Possible Cause

Solution

ELECTRICAL (Continued)

Improper or No High

Voltage (Cont.)

Faulty flow switch

Improper or no ground at

control unit

Faulty high voltage cable

Faulty control PC board

Faulty high voltage multiplier

assembly

Missing conductive sponge in

resistor tube

Faulty resistor tube assembly

Replace flow switch.

Trace and correct.

Replace.

Replace.

Check and replace.

Install.

Replace.

Isolation System

Grounded Out

Failed fluid hose

Insolation stand or charged

equip-ment too close to ground

Replace fluid hose.

Provide adequate ground distance.