INTRODUCTION

GENERAL INFORMATION

The Ransburg

Applicator Performance Test

Stand was developed to assist in determining

the applicator level of performance in an off-line

condition. Insuring the applicator functions properly

after any maintenance has been performed to it

off-line reduces the costs associated with verifying

performance during production. With line speeds

critical to the through-put of a facility, every uptime

minute counts to underwrite profitability. This Test

Stand device helps to insure the applicator per-

forms correctly when it is put into service.

The Test Stand will verify performance of single or

dual fluid applicators, bearing air, seal air, shaping

air, brake air and atomizing air. It also checks for

kV and µA electrical performance of the applicator.

The Test Stand was developed with the user and

the safety of the user in mind. The user must

become familiar with the overall function and

operation of the unit.

SPECIFICATIONS

Electrical / Physical

Power Requirements:

110/120 v AC

Air Requirements:

1” NPT (F) Inlet

3/4” ID Air Line to Stand

100 psi (6.4 bar)

(90 psig Min. @ 20

SCFM) Min.

0.3 to 0.6 Micron

Filtration

Dimensions:

Height:

67” (1702 cm)

Width:

30” (762 cm)

Length:

48” (1219 cm)

Fluids: Use distilled or de-ioniz-

ed water only for testing

Maximum Fluid

Pressure: 80 psi (5.2 bar)

Test Specification Summary

At Voltage:

90 - 100 KV

20 µa Max.

Fluid Leaks:

No pressure drop for

2

minutes

Bearing Air

Flow Rate:

1.5 to 2.5 SCFM

Turbine Air Flow

At 50K rpm:

14 SCFM Max.

Shaping Air Flow:

8 - 13 SCFM at 25 psig

17 - 21 SCFM at 60 psig

Seal Air:

9 - 11 SCFM at 30 psig

Fiber Optic Voltage: .68V at 50K RPM Min.

N O T E

> For all test stand toggle switches, with

the switch lever in the “UP” position, the

valve it describes is “ON” or “actuated.”

RMA-202 Test Stand - Introduction

6