Fluid Pump Motor Speed Control Station - Maintenance
Figure 5: Troubleshooting Guide (Continued)
Figure 5: Troubleshooting Guide (Continued)
Figure 5: Troubleshooting Guide (Continued)
Figure 5: Troubleshooting Guide (Continued)
Figure 5: Troubleshooting Guide (Continued)
Line and Motor
Armature Current
Excessive
Motor Rotates in Wrong
Direction
General Problem
General Problem
General Problem
General Problem
General Problem
Cause
Cause
Cause
Cause
Cause
Solution
Solution
Solution
Solution
Solution
1. Motor overloaded
1. Armature wires re-
versed
1. Check shunt field current. Low shunt
field current causes excessive armature
current. If field current is adequate,
check for a mechanical overload such
as a frozen pump. Also check for a
shorted motor armature.
1. Reverse armature wires, A1 and A2 to
motor.