IAI America RCS3PCR-SS8C User Manual

Page 171

Advertising
background image



11. Maintenance and Inspection

151

[Absolute encoder]

[1] Check the home position.

Turn on the controller power.

When the controller is turned on for the first time after the motor has been replaced, a battery voltage low

alarm should generate. Reset this alarm.

Next, use the PC software or teaching pendant to perform homing, and then perform an absolutes reset.

Thereafter, repeat homing several times to confirm that the actuator returns to the same position every time.

[2] Check the amount of position deviation.

The home position may have shifted slightly after the motor replacement.

To check the amount of position deviation, select a desired position number appropriate for checking the

deviation after the motor replacement, perform positioning to the selected position, and measure the

amount of deviation.

[3] Correct the deviation.

If there is a deviation when the SCON controller is being used, use home return offset distance of

parameter No. 22 to make corrections. If the SSEL or the X-SEL controller is being used, use home preset

value of axis-specific parameter No. 12 to make corrections.

In addition, after changing the parameter, perform homing � absolute reset.

[Home Return Offset Distance (SCON) and Home Preset Value (SSEL and X-SEL) Correction Example]

If, after the motor replacement, the home position became deviated by 0.1 mm in the direction of moving away

from the mechanical end.

In this case, to align it with the initial home position when the SCON controller is being used, reduce the home

return offset distance of parameter No. 22 by 0.1 mm. If the SSEL or the X-SEL controller is being used, reduce

the home preset value of axis-specific parameter No. 12 by 0.1 mm.

(Change from 2.5 mm to 2.4 mm.)

Initial Z-

phase

Mechanical end

Distance from mechanical

end to Z-phase

Home return offset

distance (SCON)

Home preset value

(SSEL or X-SEL)

Deviation: 0.1 mm

2.5 mm

[Setting at shipping

inspection]

Z-phase after

motor replacement

Initial

home

Home after motor

replacement

2.5 mm

[Setting at shipping

inspection]

Advertising