6. Inspection/Maintenance

(6)

Click the “Servo-OFF” button.

(7)

Press the emergency-stop switch.

(8)

Affix the rotational axis at the reference position by setting the plate and pin of the adjustment jig as
illustrated below.
x Set the jig after confirming that the emergency-stop switch is pressed.
x Set the jig after adjusting the rotational axis to the reference position, using the positioning mark

label as a guide.

x The top face of the stopper should roughly align with the bottom face of arm 2.

The plate and pin should
make light contact.

D-cut surface

Positioning mark label
for rotational axis

Location of positioning seal
on IX-NNC70

……/80……

Location of positioning seal
on IX-NNC50

……/60……

D-cut surface

z Always press the emergency-stop switch before setting an adjustment jig. Failure to do so may

cause the robot to malfunction and result in a serious accident.

z Pay attention to the orientation of the D-cut surface of the plate jig.

Warning