IAI America IX-NNC8040 User Manual

Page 76

Advertising
background image

70

7. Specifi

cations

Item

Specifications

Ambient temperature/humidity

Temperature: 0 to 40 C, humidity: 20 to 85%RH or less (non-condensing)

Operating
environment

Altitude

m

1,000 or less

Noise

dB

74

Robot weight

kg

62

Power supply

230 V 50/60 Hz 15 A

Allowable supply voltage fluctuation

%

10

Overvoltage category (IEC60664-1)

Category III

Controller

Pollution degree (IEC60664-1)

Pollution degree 3

*1

To move the robot horizontally at high speed, perform teaching so that the vertical axis stays as close to the top
position as possible. (Fig. 1)
To operate the robot with its vertical axis at the bottom position, the speed and acceleration must be reduced as
appropriate. (Fig. 2)

*2

Assuming PTP instruction operation.

*3

Measured at a constant ambient temperature of 20 C.

*4

Measured when the robot is operated at the maximum speed, carrying a rated load of 5 kg.

*5

The permissible moment of inertia converted to a value at the rotational center of axis 4. The offset from the
rotational center of axis 4 to the tool’ s centerof gravity is assumed to be 50 mm or less. (Fig. 3)
If the tool’ s center of gravity is furt

her away from the rotational center of axis 4, the speed and acceleration must be

reduced as appropriate.

*6

If the tool exceeds the permissible diameter, it will contact the robot inside the robot’ s range of movement. (Fig. 4)

*7

To enable the alarm LED indicator, the user must provide a circuit that supplies 24 VDC to the LED terminal in the
user connector in response to the controller I/O output signal, etc.

*8

A force of up to three times the dynamic push-in thrust may be applied at any given moment.

*9

The static thrust refers to thrust generated within the robot’ s range of operation based on a PAPR command.

*10 Based on a suction rate of 80 Nl/min (-100 mmAq).

Reference design standards: Annex I to Machine Directives, EN292-1, EN292-2, EN1050, EN60204-1, EN775

(Fig. 1)

(Fig. 2)

(Fig. 3)

(Fig. 4)

100

50

Tool’ s center of
gravity

Center of
rotational axis

Center of
rotational axis

Bottom
position

Tool

Tool

Tool

Tool

Top position

Brake power source for main unit

W

24V DC ±10% 20W

Advertising
This manual is related to the following products: