Chapter 3 Operation (Construction for Network)

45

IA Net

XSEL-R/S





Convert the bit data set in No.605 into the hexadecimal numbers.

The value to set in No.605 is 800F060F

H

.

Convert the bit data set in No.606 into the hexadecimal numbers.

The value to set in No.606 is 0FF00C0E

H

.

Reference Matching Table for Bit Data (Binary Numbers)

and Hexadecimal Numbers

Bit Data

(Binary Numbers)

Hexadecimal

Numbers

0000

0

0001

1

0010

2

0011

3

0100

4

0101

5

0110

6

0111

7

1000

8

1001

9

1010

A

1011

B

1100

C

1101

D

1110

E

1111

F




b31

b0

Station No.

63 62 61 60 59 58 575655545352515049484746454443424140393837 36 35 34 33 32

Settings in No.606

0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 1 1 1 0

Settings in No.605 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 1 1 0 0 0 0 0 1 1 1 1

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

(Covert into

hexadecimal

numbers)

8

0

0

F

0

6

0

F

Settings in No.606 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 1 1 1 0

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

Ļ

(Covert into

hexadecimal

numbers)

0

F

F

0

0

C

0

E

XSEL 5th Unit

(3 stations

occupied)

XSEL 6th Unit

(2 stations

occupied)

XSEL 7th Unit

(4 stations

occupied)

Extension I/O Unit

(4 stations

occupied)