Chapter 4

Appendix

64

IA Net

XSEL-R/S

No.

Parameter Name

Initial Value

(Reference) Input Range

Remarks

701 IA Net Shared Number of

Outputs Use

0

0 to 256 Multiples of 16

702 (For extension)

703 (For extension)

704 (For extension)

705 Extension I/O Unit Use Select

0

H

0 to

FFFFFFFF

H

Bits 0 to 3

: Slot 1 Use Select

Bits 4 to 7

: Slot 2 Use Select

Bits 8 to 11 : Slot 3 Use Select

Bits 12 to 15 : Slot 4 Use Select

(0:Unused

1:Only output to be used

2:Only input to be used

3:Both output and input to be used)

706 Extension I/O Unit No.

0

H

0 to F

H

Set the unit number of the used extension I/O unit.

(Note) Extension I/O unit is that;

x

Top station number = unit number × 4

x

Number of occupied stations = 4

in IA Net network.

707

Extension Input Port Start

Number at Extension I/O Unit

Slot 1 Fixed Assignment

-1

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

708

Extension Output Port Start

Number at Extension I/O Unit

Slot 1 Fixed Assignment

-1

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

709

Extension Input Port Start

Number at Extension I/O Unit

Slot 2 Fixed Assignment

-1

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

710

Extension Output Port Start

Number at Extension I/O Unit

Slot 2 Fixed Assignment

-1

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

711

Extension Input Port Start

Number at Extension I/O Unit

Slot 3 Fixed Assignment

-1

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

712

Extension Output Port Start

Number at Extension I/O Unit

Slot 3 Fixed Assignment

-1

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

713

Extension Input Port Start

Number at Extension I/O Unit

Slot 4 Fixed Assignment

-1

-1 to 3999 1000+(Multiples of 16)

(Setting is invalid if set to -1)

714

Extension Output Port Start

Number at Extension I/O Unit

Slot 4 Fixed Assignment

-1

-1 to 6999 4000+(Multiples of 16)

(Setting is invalid if set to -1)

715 Extension I/O Unit Error

Monitor

0

0 to 5

0 : No Monitoring

1 : Monitoring

2 : Monitoring

(Not to monitor 24V I/O power related error)

3 : Monitoring

(To monitor only 24V I/O power related error)

4 : Monitoring (makes 24V I/O Power Supply

Related Error message level)

(Note) There are some exceptions

(Note) When it is set to 0 (= Not monitored) or 2

(=24V I/O Power Supply Related Error not

monitored), a system error would not be

generated even in an error related to 24V

I/O power supply, but the actual output

would not be executed for the protection

of the extension I/O unit.