Ia net, Xsel-r/s, Chapter 4 appendix – IAI America XSEL-S User Manual

Page 68

Advertising
background image

Chapter 4

Appendix

62

IA Net

XSEL-R/S

Listed below are the parameters related to IA Net. Refer to XSEL-R/S Instruction Manual for the

parameters of the XSEL controller main unit.

x

I/O parameters

No.

Parameter Name

Initial Value

(Reference) Input Range

Remarks

1 I/O Port Allocation Type

1

0 to 1

0 : Fixed Allocation (Recommended when IA Net

is used)

1 : Automatic Allocation

(Note) Priority of I/O Port Assignment when

automatically assigned

Input Port No.0 to 299

Output Port No.300 to 599

1) Network I/F Module 1

2) I/O Slots 1 (I/O 1) Mounting Board

(Note) I/O Slots 1 (I/O 1) Assigned for the

continuously mounted range from

mounting board = for safety

(Note) Priority of extension I/O ports at automatic

assignment

Input Port No.1000 to 3999

Output Port No.4000 to 6999

1) Network I/F Module 2

2) Extension I/O Unit

3) IA Net

20 Input Filtering Cycle

2

1 to 9

Input signal is identified after the condition is

retained for a period with two times or more of the

value set in this parameter.

602 IA Net Top Occupied Station

No.

0

0 to 63

Set the smallest number in the station numbers

(settable range from 0 to 63) that the controller

occupies.

603 IA Net Resizing Station No.

0

0 to 63

Station number to optimize the communication

cycle time at the IA Net startup

(Note) Have the same value set in common for all

the controllers in the same network.

(Recommendation: Set the smallest value

available to assign in all the station

numbers available for assignment in the

shared memory.)

604 IA Net Final Station No.

63

1 to 63

Final station number in the same network

(Note) Have the same value set in common for all

the controllers in the same network.

(Recommendation: Set the biggest value

available to assign in all the station

numbers available for assignment in the

shared memory.)

605 IA Net All Connected Station

Patterns (31-00)

0

H

0 to

FFFFFFFF

H

With 0: Disconnected and 1: Connected, make the

connection conditions of Stations No.31 to No.0 in

bit patterns and convert them into the hexadecimal

numbers to input.

606 IA Net All Connected Station

Patterns (63-32)

0

H

0 to

FFFFFFFF

H

With 0: Disconnected and 1: Connected, make the

connection conditions of Stations No.63 to No.32

in bit patterns and convert them into the

hexadecimal numbers to input.

607 IA Net Error Monitor

1

0 to 5

0 : No Monitoring

1 : Monitoring

2 : Monitoring (Monitoring only on the errors

related to link error)

(Note 1) There are some exceptions

(Note 2) IA Net Link Error occurs when the

duration of the condition being in the

network link error exceeds the value set

in IA Net Network Link Error

Confirmation Timer. (Refer to I/O

parameter No.608)