Chapter 4. Programming

(2) Movement Description

1.

X and Y-axis return to home and wait.

2.

Worker sets work on X-Y-table, then turns start switch (SW) ON.

3.

X-Y-table moves to position No.1 then outputs riveting command to the riveting unit.

4.

After riveting is completed, wait for completion signal input. Repeat the same procedure for position No.2 and position
No.3.

5.

After riveting at all three positions, axis returns to home.

Repeat the same procedure as above. The operating position, external I/O assignment and flowchart are as follows.

Section

I/O #

Signals

Specifications

S

u
p
e

r

S
E

L

I

020

Start Command

Push Button SW

021

Rivet Complete

Contact Signal

O

310

Rivet Command

DC 24V

Flag In Use From 600

I/O Assignment

Flowchart

Operating Position

l

P1

P3

P2

XY Table

Work

l

l

l

P4

Riveting unit

N

Work Counter = 2

Move to Rivet Position

Rivet Command ON

Rivet Complete

Rivet Command OFF

Operation End

Y

Y

Y

Start

Work Counter +1

N

в

в

в

в

в

в

в

в

в

N

Start

Y

Move to Position No. 1