IAI America TT-C3 User Manual

Page 146

Advertising
background image

136

INTELLIGENT ACTUATOR

Chapter 4 Commands

2.

Explanation

of

Commands

z DCL (Set deceleration)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

DCL

Deceleration

Prohibited CP

[Function] Set the travel deceleration of the actuator.

The maximum deceleration will vary depending on the load and model of the actuator
connected.
The deceleration is set in G and may include up to two decimal places.

(Note)

If the position data contains no deceleration AND deceleration is not set by a DCL command,
the actuator will move based on the default value set in “All-axis parameter No. 12, Default
deceleration.”
A DCL command cannot be used with CIR and ARC commands.

[Example]

DCL

0.3

Set the deceleration to 0.3 G.

(Note)

Setting a deceleration exceeding the specified range for the actuator may generate an error.
It may also result in a failure or shorter product life.
Maximum acceleration: 0.3 G for the gate type and 0.2 G for the cantilever type

Advertising
This manual is related to the following products: