Other parameters – IAI America TT-C3 User Manual

Page 322

Advertising
background image

312

INTELLIGENT ACTUATOR

Appendix

Appendix

Other Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

38

PC/TP data protect
setting (Symbol,
parameter)

0H

0H to

FFFFFFFFH

Bits 0 to 3:

Protect type (Parameter) (0: Read/write, 1:
Read only, 2: No read/write)

Bits 4 to 7:

Protect release method (Parameter) (0: Special
operation)

Bits 8 to 11:

Protect type (Symbol) (0: Read/write, 1: Read
only, 2: No read/write)

Bits 12 to 15:

Protect release method (Symbol) (0: Special
operation)

* Referenced by the PC/TP (PC software version 2.0.0.42 or

later and TP application version 1.09 or later)

39

(For future expansion)

0H

0H to

FFFFFFFFH

40 EEPROM

information

check type

3H

Reference only

For adjustment by the manufacture

41 Hardware

information

check type

E0H

Reference only

For adjustment by the manufacture

42

Hardware test type

7H

Reference only

For adjustment by the manufacture

43

Special monitor type

0H

0H to

FFFFFFFFH

Change strictly prohibited unless specified by the manufacturer.

44 (For

expansion)

0

45

Special start condition
setting

0

0H to

FFFFFFFFH

Bits 0 to 3:

Enable start from PC/TP in AUTO mode = Used exclusively
by the manufacturer (0: Do not enable, 1: Enable)

Bits 4 to 7:

PIO program start (Input port 000)
Single start selection (0: Normal, 1: Single start)

* When single start is selected, the next PIO program start

(input port 000) will not be accepted as long as a program
with the same program number as the one started by the
last PIO program start (input port 000) is running.

Bits 8 to 11:

Permission of auto program start when all-operation-
cancellation factor is present
(0: Do not permit, 1: Permit)

Bits 12 to 15:

Permission of ON edge acceptance for PIO program start
(input port 000) when all-operation-cancellation factor is
present
(0: Do not permit, 1: Permit)

* This parameter specifies an ON-edge acceptance

condition. If the starting condition is not satisfied, an “Error
No. A1E: Start condition non-satisfaction error” will
generate.

PC: PC software
TP: Teaching pendant

Advertising