IAI America PCON-CFA User Manual

Page 218

Advertising
background image

5. Flow and Commands of Basic MECHA

TROLINK Communication


210



[3] ID_RD commands

Command Code

Name

ID_RD 03H

ID

read

command

Command to read the controller ID
You can select the ID information based on the DEVICE_CODE value.
You can check if the process is completed by checking CMDRDY=1 in the STATUS field or requested ID data.

Field (Signal) name

Value

Description

0H

The product model name (expressed in ASCII) is returned in a response.
PCON-C: 50434F4E2D432D4D4C
PCON-CG: 50434F4E2D43472D4D4C
PCON-CA: 50434F4E2D43412D4D4C
PCON-CFA: 50434F4E2D4346412D4D4C
ACON-C: 41434F4E2D432D4D4C
ACON-CG: 41434F4E2D43472D4D4C
SCON-CA: 53434F4E2D43412D4D4C

1H

The product serial number (expressed in binary) is returned in a response.

2H

The version information (expressed in binary) is returned in a response.

DEVICE_CODE

FH

The vendor ID and the vendor name are returned in a response.
Vendor ID = 202 (CA

H

)

Vendor name = IAI (494149)

OFFSET

47 to 0

Specifies the position to read the selected DEVICE_CODE content

SIZE

8 to 1

Specifies the number of data to be read [in bytes]

y Communication data format

Byte Command

Response

0 CDRW(03H) ACK(01H)

1 ID_RD(03H) ID_RD(03H)

2 0

ALARM

3 0

4 0

5 DEVICE_CODE

DEVICE_CODE

6 OFFSET

OFFSET

7 SIZE

SIZE

8 0

: 0

15 0

16 WDT

RWDT

17 0

0

: 0

0

31 0

0



STATUS

ID[0]

:

ID[7]

Advertising
This manual is related to the following products: