8 wiring the emergency stop circuit, 1 cutting off the drive signal (standard) – IAI America ACON-PO User Manual

Page 34

Advertising
background image

24

3. Installation and W

iring

3.8

Wiring the Emergency Stop Circuit

3.8.1

Cutting Off the Drive Signal (Standard)

Shown below is an example when the emergency stop circuit of the entire system is used to actuate an emergency
stop on multiple controllers.
However, the emergency stop switch on the teaching pendant cannot actuate an emergency stop of the entire system.

External EMG
switch

EMG signal
detection (H)

Time

constant

Drive stop
signal (L) Motor

drive

circuit

External EMG circuit

Motor power
supply

Normally these
terminals are
connected by jumper
wires. If the
applicable safety
category requires
cutoff of the motor
drive source, use the
following circuit.
(The motor drive
source will be cut off
at the same time the
EMG switch is
operated.)

The brake is turned
on/off automatically
based on servo
on/off actions.
To release the
brake manually,
close the brake
release switch. The
brake will be
released.

* The user must

provide the brake
release switch.

(Switch)

24 VDC
Contact capacity
0.2 A or more

EMG switch of

teaching pendant

Connection

detection circuit

Controller power
supply

Brake release

switch

2nd controller

nth controller