3. Installation and W

iring

3.10 Connecting the I/O Shield Cable

Cable model: CB-PACPU-PIO***
(Note: *** indicates the cable length. (Example) 2 m: 020)

Pin No.

Color

Name

Remarks

1

Black

External 24 V

2 White/Black External

ground

If the controller is used in the open collector mode, also use this pin
for the COMMON signal for command pulses.

3 Red

SON

Servo-on

signal

4

White/Red

TL

Torque-limit selection signal

5 Green

HOME

Homing

signal

6 White/Green RES/DCLR

Reset

signal/deviation-counter clear signal

7 Yellow

SV

Servo-on

output

8 White/Yellow

INP/TLR

Positioning

complete signal/torque limit signal

9

Brown

HEND

Homing complete signal

10 White/Brown *ALM

Alarm

signal

11 Blue

Command

pulse/PP

12

White/Blue

Command pulse PP

Not connected if the controller is used in the open collector mode.

13 Gray

Command

pulse/NP

14

White/Gray

Command pulse NP

Not connected if the controller is used in the open collector mode.

-

-

FG

Shield (connected to the enclosure)

No connector

Housing
Contact

Shield cable

Round
terminal