4. SCON-CA

226

(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)

Signal type

Bit

Symbol

Contents

Details

Current

position

32-bit

data

-

32-bit signed integer indicating the current position

The setting unit is 0.01mm.

(Example) Reading: 000003FF

H

=1023 (decimal)

=10.23mm

* When the value is read in hexadecimal notation, the negative

figure is expressed as a complement of 2.

4.8 (2)

Command

current

32-bit

data

-

32-bit integer

The electrical current presently specified by a command is indicated.

The setting unit is mA.

(Example) Reading: 000003FF

H

=1023 (decimal)

=1023mA

4.8 (2)

Current

speed

32-bit

data

-

32-bit signed integer indicating the current position

The current speed is indicated.

Positive value: The actuator is moving in the direction opposite home.

Negative value: The actuator is moving in the direction of home.

The setting unit is 0.01mm/sec.

(Example) Reading: 000003FF

H

=1023 (decimal)

=10.23mm/sec

*

When the value is read in hexadecimal notation, the negative

figure is ex

pressed as a complement of 2.

4.8 (2)

Alarm code 16-bit

data

-

16-bit integer

When an alarm is issued, the alarm code is output.

When any alarm is not issued, it is “0H”.

Refer to the Operation Manual for the controller main body for the details

of the alarms.

4.8 (2)

b15

EMGS Emergency stop: An emergency stop is actuated when this signal turns

ON.

4.6.11 (2)

b14

PWR Controller ready : This signal turns ON when the controller becomes

ready.

4.6.11 (1)

b13

ZONE2 Zone 2:“ON” for the current position within the zone set range

4.6.11 (12)

b12

ZONE1 Zone 1:“ON” for the current position within the zone set range

4.6.11 (12)

b11
b10

b9

-

Unavailable

-

b8

RMDS

Operation Mode Status:

This signal is OFF when the current mode is AUTO, or ON when the

current mode is MANU.

4.6.11 (19)

b7

BALM Absolute battery voltage low warning: This signal turns ON when the

voltage drops.

4.6.11 (28)

b6

-

Unavailable

-

b5

PSFL

Pressing and a Miss: This signal turns ON when the actuator missed

the work part in pressing operation.

4.6.11 (23)

b4

SV

Operation preparation end: This signal turns ON when the servo turns

ON.

4.6.11 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

4.6.11 (3)

b2

MOVE Moving Signal: This signal remains ON while the actuator is moving.

4.6.11 (9)

b1

HEND Home return completion: This signal turns ON when home return is

completed.

4.6.11 (6)

PL

C

in

pu

t

Status signal

b0

PEND Positioning completion signal: This signal turns ON when positioning is

completed.

4.6.11 (10)