2.

ACON-C/CG, PCON-C/CG

23

(1) PLC address configuration (* “n” indicates the first address of each axis.)

Parameter

No.84

ACON/PCON side

DI (Port No.)

PLC side output

address (bytes)

ACON/PCON side

DO (Port No.)

PLC side input

address (bytes)

0

0 to 15

n+0, n+1

0 to 15

n+0, n+1

(Note) Be careful of using duplicated node addresses.

(2) I/O signal allocation for each axis

The I/O signals of each axis consist of one input word (1 word = 2 bytes) and one output word in the I/O

areas.

x

This is controlled by ON/OFF bit signals from the PLC.

PCL output

Address (* “n” indicates the first output address of each axis.)

PCL input

Address (* “n” indicates the first input address of each axis.)

Controller

input port

number

1 word = 2 bytes =16 bit

n+0 n+1

Controller

output port

number

1 word = 2 bytes =16 bit

n+0 n+1