5. V

ision System I/F Function Setting

33

5.8.1 Initial Settings for Simple Calibration

(When EZ-110XL camera is used)

Conduct the initial settings following the steps below with using the Cognex Setup software (In-Sight
Explorer) or PC software for XSEL.
(Note) It is necessary to redo the initial settings (1) to (3) if the version of In-Sight Explorer is

updated.

ڏ

Please contact us for the files necessary for the initial settings.

[Initial Setting 1]
Copy the file “IAIClassLibrary.dll” stored in the PC software installation CD and put it into the folder
stated below:

¥Program Files¥Cognex¥In-Sight¥In-Sight Explorer *.*.*
(*.*.* indicates the software version: applied in 4.4.1 and later)


[Initial Setting 2]
Copy the file “IAICalib_EN.cxd” stored in the PC software installation CD and put it into the folder
stated below:

¥Program Files¥Cognex¥In-Sight¥In-Sight Explorer *.*.*¥Snippets¥EasyBuilder
(*.*.* indicates the software version: applied in 4.4.1 and later)

[Initial Setting 3]
Start up In-Sight Explorer.
Select Options in In-Sight Explorer System Menu and tick on “Use English Symbolic Tags for
EasyBuilder” in the User Interface items.