Set port internal-error-shutdown, Command mode, Description – Avaya P580 User Manual

Page 452: Syntax, Sample output, Systems, Set port internal-error-shutdown -20

Advertising
background image

Chapter 21

21-20

Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

set port internal-error-shutdown

Command Mode

Global Configuration.

Description

Sets switch ports to shutdown if their rate of internal errors exceeds the
threshold setting. To set the threshold, use the set-internal-error-threshold
command. For information on this and other IEDR commands, see

Chapter 18

, “

NEDR and IEDR

.”

Syntax

Sample Output

The following example enables IEDR on all ports on the module in slot 3.

(configure)#

set port internal-error-shutdown 3 enable

Systems

P550R, P580, P880, and P882.

To Enable:

set port internal-error-shutdown {<mod-num> | <mod-
swport-spec>
| all-ports} enable

To Disable:

set port internal-error-shutdown {{<mod-num> | <mod-
swport-spec>
}| all-ports} disable

Table 21-18. Parameters, Keywords, Argument

Name

Definition

{<mod-num> | <mod-
swport-spec>
}

The slot number of the module, and, either port
number, or range of port numbers. Enter the port
ranges in the format Px-Py. For example:

• To specify port 1 on the module in slot 3, enter

3/1.

• To specify ports 1 through 5 on the module in

slot 3, enter 3/1-5.

all-ports

Enables or disables IEDR on all ports on all modules in
the switch.

Advertising