Ip ospf poll interval, Command mode, Description – Avaya P580 User Manual

Page 398: Syntax, Sample output, Systems, Ip ospf poll interval -22

Advertising
background image

Chapter 19

19-22

Command Reference Guide for the Avaya P580 and P882 Multiservice Switches, v6.1

ip ospf poll interval

Command Mode

Interface Configuration.

Description

Specifies the poll interval time. The valid range is 1 to 3600 seconds. The
default setting is 120 seconds. The no command restores the default setting.

Syntax

Sample Output

The following command sets the poll interval time on interface 123 to 2000
seconds.

(config-if:123)#

ip ospf poll-interval 2000

Systems

P550R, P580, P880, and P882.

To Configure:

ip ospf poll-interval <seconds>

To Restore Default:

[no] ip ospf poll-interval

Table 19-15. Parameters, Keywords, Arguments

Name

Definition

<seconds>

Time in seconds between retransmissions. It must be greater
than the expected round-trip delay between any two routers on
the attached network. The range is 1 to 3600 seconds.

Advertising